Meaning of GlobVars

<< Click to Display Table of Contents >>

Navigation:  »No topics above this level«

Meaning of GlobVars

The Global Variables are set and maintained by the Speer IT servicedesk. These settings, amongst others, are used to determine how Cocon handles specific items.
They may be used to set specific behavior for specific customer environments.
 

 

Globvar Name

Description:

LngFindNearest

For searching the nearest number of locaties.

AantalKabelsNN

Determines the amount of objects found with the SDO_NN.

AccesspointPatchTypes

These type of accesspoint can be used to create a patch in an FTTH environment. (default Mast)

AdresString

If filled, overrides the value of adressdata shown when making a print of the geography.

AdresString2

If filled, overrides the value of adressdata shown when making a print of the geography.

AdresveldenBedrijfbestand

Designed to record from the company file which fields represent street, housenr, add, PC and city in that order.

Designed to suppress positions in several reports, e.g. terminationunit name or terminatinunit type when it partially exists from a given (series of) string(s).

AfsluitenProjectProjectDBControles

Ensures db controles are run when closing a project.

AltTraceGetRecords

This field allows to set an alternative customercode, for running database controles.

AutoSetResDate

Place reservationdate and reservationenddate on today, automatically, when the date is set to >= 100 days ago.

AvailableFrameNeededForConnect

Used to determine in routing if an adres is connected, if 1 there should be a frame available for customer connections.

BBEquipmentLimitInKM

Used for routing

BCCRUDEndpoint

Endpoint for BCCRUD

BCEndpoint

Endpoint for BC check while processing a post-connection through Cable-ID.

BackGroundLokaalVerplicht

Locale obligatory streetpro pad.

BeheerAgendas

J = all agendas and reoccurring items may be used.

BepaalUniekAccesspoint

Sets the specific naming for accesspoints for this environment.

Borgen_Redundancy

If a sectionname is remove, by this setting this globvar a check on redundancy is performed by a server/client relation.

BuilProgressInPlanon

Determines if the FTTH build progress through buildfiles is maintained in the PLANON scheme.

BuildingAddressConnected

Adres is connected if the adres is found in place as a building.

BuildingGeoConnected

Adres is connected if the adres's coordinate is within building.

BuildingTabconDirectConnected

Adres is connected if the coordinate is within building and ends on a tabcon endpoint.

BuildingTabconGeoConnected

Adres is connected if the coordinate is within building and near a tabcon endpoint.

CTW2ENVIRONMENT

A different name for the klantcodelang for CoconTheWeb. if left empty the CoconTheWeb environment is assumed to be equal to the Cocon environment.

CableField

Handles which field of ospspan is shown, between the () in the objectlist. When shown by default this doesn't exist and the capacity is shown instead.

CableOwners

Cable owners that are considered part of the network.

CablePackVersion

Setting for turning on/off the option create CablePack.

CadAcceptatietool

If used, the drawing is processed in an additional tool, which checks drawings before and after delivery, according to a set template.

CadBeheerTabel

The maintain cad drawing checks this table in klicon to find the right drawing (default= TABGEUL2)

ChangeDevicePortOperator

Customer id of the active operator in the ChangeDevicePort webservice call.

CheckBuisVerschilLengte

For checking on a duct differences, when cutting / undoing the cut / extending a duct.

CheckPrinterAvailable

When set, 0 = No, 1 = Yes, checks if there is a printer available to the user.

CloseCoconOnError

Close cocon after a crash? 0=No, 1=Yes

CoordSys2

Second coordsys

CoordSysNumber

Oracle Coordsys value used for geodata

CoordSysNummer2

Second SRID

CountryCode

If set, a coordinate system is enforced on an environment

CustomerCode

Short customer code.

Cyclomedia

Login data for Cyclomedia GlobeSpotter. If left empty, the Cyclomedia menu item will not be shown.

Cyclomedia2

Login data for Cyclomedia GlobeSpotter. If left empty, the Cyclomedia menu item will not be shown.

DGZones

When used, the zones.tab file in location supportfiles\zones\ is loaded during the startup of the geography.

DUCTSPLICEInUse

1 = DUCTSPLICE instead of  BUISVERBINDINGNUMMER

DefSepSectionname

Determines if the sectionname must have a special sorting, separation or alphanumerical code.

DefZoomlvlAP

Value for the default zoomlvl, when placing a new accesspoint.

DefaultLanguage

Sets the default language for the environment, if the user has not yet set one.

DefaultSpanOwner

Default cableowner

Detailstatus_no_mark

Indicates at what detailstatus there should not be markings.

DrawingTypes

Autocad build drawingtypes.

DuctOwners

Ductowners, belonging to a customer.

Email_Borgen_Redundancy

When changes are made to section names, an email will be sent to this e-mail address.

ExcludeProjectDC

Condition for DC.

ExcludeProjects

Exclude certain (FTTS) projects from routing.

ExterneOracleAddressTable

Definition of the scheme and table/view name in which the external address data for the customer are found.

ExtraHHDistanceInM

Used for routing

FiberStrike

Allow the use of import for fiberstrike  (1 = allowed)

ForeignOwnerUpdates

Determine if changes are allowed on objects owned by another operator. (e.g. cutting a cable)

GebruiktDoorGeheleBuisverbinding

Set to use the field for 'use on entire ductconnection', when spanid is not yet placed.

GemiddeldeLengteSpoorboring

Standard value for routing

GetDecimalSepOracle

For modification of data to a KML file.

GetFileMD5HashCode

Set to determine if a .dwg  has a hashcode.

GoogleMapsUrl

Locale url for allowing googlemaps. If not set, the default url: https://maps.google.com is used.

HoogteEenheidVanaf1

J = the position 0 of a frame is blocked and a extra position may be entered here. (e.g. 1 t/48 instead of  0 t/m 47

InCitrixServers

Citrix servers of the environment

IsCoconTheWebOmgeving

This environment has the option to allow users access to their CoconTheWeb environment.

KeepDetailstatus

Indicate if a detailstatus should be kept if an object is confirmed. The value inserted determines from what value the detailstatus should be kept. Left empty indicates the status is removed.

KlicView

Indicate what view should be used if a GML file is generated in Cocon.

KoplasKabelwerk

The cableworknumber used as default for customers confirming a headsplice-situation.

LasschetsExtentiemm

Due to several macro's which are unavailable when saved in .xlsx format, the FTTHlas in this environment is saved in a.xls format.

LeeftijdBestandenExtLeveranciers

Determine how old a file with external suppliers is allowed to be before a new one must be created.

LijnbenamingContractRelatieVerplicht

When the sectionname is linked to a connect, a valid contract with contactperson must be selected.

LijnbenamingInKlantcontract

When the sectionname is not found while searching, a check is done on contracts to see if the exists there and is linked to another sectionname.

LngFindNearest

Value for the number of searchresults in edit span and insert frame. Determines the maximum sizez of the downdown when searching objects.

LngFindNearestBDG

Value for the number of nearest buildings when inserting a frame. default = 5.

Loc1

Location type for the main labels

LocationType1ServiceNeed

Is a service required during routing to locationtype1.

LocationType2ServiceNeed

Is a service required during routing to locationtype2.

MAX_LIST_RESULTS

Value for the maximum amount of results shown.

MIRouterinTabUsers

All routing adresses in 1 tab file in the temp directory.

MIRoutingTabUsers

Required for creating an end-to-end routing in the mapinfo file.

MaakSectieInNeis

When set to J a new sectionname is created through a webservice. Created in NEIS. Customer Specific Globvar.

MaakSectieInNeisHost

Service where the webservice is located for use of NEIS. Customer Specific Globvar.

MaakSectieInNeisPassword

Password for the webservice for use of NEIS. Customer Specific Globvar.

MaakSectieInNeisUsername

Username for the webservice for use of NEIS. Customer Specific Globvar.

MailNaAansluitingen

E-mail addresses for the results of batchprocessing post-connections (FTTH operators)

MapDelayTime

Processing time in msec that setstatustxt used before continueing.

MaxKabelLengte

Maximum cablelength, to determine cable in the duct.

MaxStraightBlowLengthInM

Used for routing.

MaxZoomKML

Maximum zoom for creating a .kml file.

Maxlengte_Naamdeel

Set the maximum length for a objectname.

MinLengteLijnbel

Set the minimum length for sectionnames.

MinLengteWaterboring

Set the minimum length for a waterrelated drilling.
Default value for routing.

NaamAanb

Short notation of supplier for creating a cablepack

NaamDeel

Return this name as a value when a OLO deviates from the 1 letter for the generation of unique sectionnames.

NegeerLengteInvoerKabelInBuis

Set if there should be a check on length on inserting a cable.

Netbeheer

Allow for multiple muteers to maintain a cablework (FttH projects) in a single environment.

NewDemping

Use the new attenuation.

NieuweKastindeling

Set to show the new frame layout. (J / N ) Some functionality depend on this setting.

NoHyperlinkTab

Set to J or blank to show a hyperlink registratie through Cocon (tabbor etc.)

OnlyOnePlannedPatchOrder

If set to 1, there is only 1 planned patchorder allowed.

OpenFileBlocked

Set to J or N to save an openfile instead of opening.

Overview_tablename

Set the name of the table used for the overview, viewing the network a higher altitude.

PercExtraLengteWaterboring

Default value, used for routing.

PlanonLogin

Login data for WorkOnPlanner

Planon_Connection

Connect string for the right scheme and the right instance.

Planon_Url

URL for usings Planon within Cocon (e.g. inserting DP address)

PreFixLengthFTPMap

Value for the length of the FTP pad, used for copying files with to much length after import.

Value for the maximum length, determined before copying the files. {location}

ProjectDocStatusVoorAfsluit

The minimum value of statuses in the project documents, before it's allowed to close the project.

RefreshGebouwenNietDirect

Setting to prevent refreshing the building layer by default.

Repairtoolmd5locatie

Set the location for the repairtool files. Check on files before the drawings are delivered.

RouteTabelInclToekomstig

Check for future network to be taken into account when generating a routingtable.

RoutingAPTypes

AP types used for routing

RoutingBuild

Is used during routing to determine the duration of the routing (no possibility to set a value)

RoutingLocationType1

FiberLight POP types

RoutingLocationType2

POP types 2 (bijv. Vodafiber POPs

RoutingOwnerChangeTypes

Types where it is free of charges to change network-owner

RoutingPatchTypes

Types where it is allowed to patch, used for routing.

SRID

Parses the coordinate system
Geeft een coordsysteem voor geo-objecten terug indien gebruikt

SchouwOnly

Value for the type of buildings that should be printed with a checkbox on the sitesurvey form, separated by a | for several types of building.

SendAgendaItemExternal

Set if the new method of 'send agenda items' is used.

SendAgendaItemExternalLOG

Activates the new xmlStyling . The number represents the xml version. If  var is 0 or null the old layer method is used

SoortkabelwerkByWorkon

Set to a different value (default value = n) to ensure that the project progress combobox cannot be set manually.

SpecialeBoringen

Used for specification of certain drilling types, e.g. settings styles.

SyncEnclosurePoorten

Set if changes to ports on the cable must changed in the spliceunit or vice versa.

TabconAllTabconUsedTabconEmpty

During the processing of a batch these layers are discarded.

TabconShareContents

Share the contents of the Tabcon, or keep it private. (yes/no)

TeOnderdrukkenFictievePosities

Set to suppress the positions, when terminationunit or terminationtype (partially) consists of a given string.

ToonAdress_PROJECT_UNKNOWN

Only show addresses linked the cablework Unknown.

ToonFTTHToolbar

Show/Hide the FttH toolbar in the geography.

TubenrOpLasschets

Set to j/n to place/hide the tubenumber in the splicescheme.

UitbeheerRealtime

Used for mainting drawings.

UseDateNowForInstdateDuctbankCommitProject

When confirming the project, the 'now' date is used as installation date for the ductbanks.

UseOfSMS

If set to j, the environment can use logon accounts. (Txt-service used for registering entrance/work on/exiting Accesspoints).

ValidateOpheffingsLas

Extra check on the status of cables in splices that are 'reserved' and shoul dbe 'in use'

VerstuurMail_wijzig_vezelstatus

Set to j to send an email to the 1e and 2nd contact person, when fiberstatus is change from 0,1,2 to 3, 4, 5, 6, 7, 8 or 9 and vice versa.

VisualStyles

Default visual style for presentation in Cocon11

WithPatchIcoon

Set to show an icon in column 1 when there is a patch placed, in the terminated fibers report.

WorkOnFieldUploadsFolder

Set the location for the uploaded files. If left empty, the linked files directory is used.

WorkOnPlannerInfo

Connection data for WorkOnPlanner

ZOOM_LVL_OVERVIEW

Settings for the overview layer.

ZoekonOmgeving

Search on environment.

as-built - grid

Value for use with acadvalidator. Hands the template (asbuilt) for the projectstructure(as-built - grid)  with the check: 'uit beheer geven document'

autstatususer

If y, on this environment users may be authorized for status changes, not just groups.

bAccesspointToevoegen

Set to j to allow a placing an accesspoint, when a cable is placed outside of an existing valid endpoint.

bAfstandBepalenAlleenNaarTabconUsed

Set to j to use only Tabconused to determine the distance to the network.

bAlternateLanguage

Used to set a customer language in the maintain customers window.

bAutoCompleteCombo

Set to use the autocomplete in the Cocon 11 combobox. Comboxes will not load their full dataset, but search while the user enters a string.

bAutoNoSpliceToegestaan

Set to j to allow a no-splice connection on the next cable, while inserting a cable.

bAutoTrajectNaam

Set to automatically generate a ductroutename, based on ductnames.

bBeheerOwner

Set to j to allow an owner to be set while inserting of changing a ductroute.

bBeheerRouteKosten

If the value is set to other then n, the routing cost may also be maintained.

bBoringExternOokOranje

Set to change the drilling color to orange when set to an external owner. certain exception apply.

bBoringHyperlink

Set to j to allow for a hyperlink to be made on a drilling.

bBuisnummerUniek

Set to j to check for unique ductnames.

bCTW_LIVESYNC_ENABLED

Set to j when a dbexport is not exported. and set to n when an export is available and livesync is active.

bCablePackCablesInvisible

Set to j to make cables created from the cablepack invisible.

bCheckFreeDiskSpace

Set to j to check if there is 1 Gb of free space available in the apps diretory when starting Cocon. Admin and batchjob are exempted.

bCombineEnclosureComments

Set to combine the enclosure of splicetray and enclosure.

bDuitseFtthStraat

Set to determine the German FttH street.

bExtraSectieVelden

Set to j to maintain more fields in the maintain sections window.

bFTTHOperator

Set to exclude the series 1000 t/m 9999 in searches for locations.

bFilterOpGlasMogelijk

Set to filter glass.

bHideCableNameSLD

Set to J to hide the cablename in the SLD.

bIMSkoppeling

Set to J when a customer has an IMS link.

bIsNlInput

Set any new termination units to Voorzijde, instead of Front or Achterzijde instead of Back.

bKabelWerkDetailStatus

Set to k to allow changes to the detailstatus of the entire cablework.

bKabelsOpLasschets

Set to determine of a cablename must be placed on the details line of the splice scheme. Scheme becomes a landscape format.

bKlantDefaulServer

Set to automatically generate a server with a contract.

bKnipAccEncMetBuisVerplicht

Set to determine if a cut with accesspoint/enclosure on a ductroute is mandatory.

bLaadcadgrid

Set to j to stop cadgrid from loading, set to n to load.

bLeverancierValuesVerplicht

Set to force inserting attenuation and length when inserting a new cable from an external owner.

bLeverancierVerplicht

Set to force setting the owner when inserting a new cable.

bLoskoppelenObjectenToegestaanInKabelwerk

Set to allow objects to be removed from a cable work.

bMIReadOnly

Set to j to always open the geography to read-only. To edit, use the option from the contextmenu.

bMIReadOnlyFilesLocal

When bMIReadOnly is set to j, move the tabfiles to the CoconAppdata location.

bMagKabelwerkenInvoerenOpbasisVanExcel

Allow for cableworks to be imported based on Vav Excel.

bMagOpenbaarRegister

Set to allow a status to be filled in the insert duct window, when wion registered.

bMapAuth

Set to allow authorization on the map tasks.

bNonMapAuth

Set to j to allow contractors to see other projects than those assigned to them.

bOTDRviewer

Set the location where the OTDR viewer is installed, separated with a ;

bPackProjectDocuments

Set which cablework documents should be packed. Can be set to remove the original documents.

bPlannedWorksVrijeNaamkeuze

Set to allow use of another planned work name, instead of the default, determined by the system.

bPostcodeVerplicht

Set to make the area code mandatory

bSendAgendaItem

Set to send the agenda item to a user, when an incident takes place.

bShowBaanvak

Set to show 'baanvakgegevens'. Customer specific

bTochTrajectRouteren

Set j to allow operators to use routing. Set to n to remove the routing button in FttH.

bToonPoort

Set to j to register ports on the splice screen (gco) , set to n to register on the cable.

Poorten registratie in het lasscherm (standaard =j  wel wijzigen)

bToonSheetsIgnoreError

Set to n to hide the detailssheet if errors occur. Set to * to show the sheet, but does not show the erroneous details.

bTraynummerAlfaNumeric

Set to j to allow the use of A / AB as the traynumber.

bUseBuildingAlias

Set to j to allow use of alias names, and editing aliases.

bUseServicePrio

Set to use servicepriorities on sectionnames.

bUseTellerTable

Set to j to generate unique string names for objects based on Oracle table value.

bVerwDocsBijAanbieden

Set to remove the old source-document when it is offered for acceptance.

bVulGatenOp

Set to 0 to stop using unused numbers while creating new unique names. Change to another value to use the minimal value.

bWDMinOutages

Set to allow for the outage function to account for the WDM.

bskip_connected_customers

Set to skip the conntected_customers table during the geocoding_file process.

cmdTrajectRouteren

Set to other then j to stop the environment for routing, due to the new routing style.

dExtraLengthCableFTTH

Additional length on the cable, used on the StuklijstFTTH

dExtraLengthDpFTTH

Additional length on the cable, used on the StuklijstFTTH

kabelbezetting_check

If not set, the batch 'kabelbezetting_check' checks all cables and discards any settings from the maintain capacity report.

lAanmeldAccountsUrenOud

Set with a number to specify if the environment uses logon accounts. (Txt-service). The number is the timewindow (hrs) afterwhich it's shown.

Set to 0 to disable.

lMaxRecords

Set to the max number of search results to return.

lMaxZoomKmVoorImportCad

Set the maximum zoom level for the importing of a CAD file.

lMaxZoomVoorOpenenBGT

Set the maximum zoom level for the BGT layering.

lMaxZoomVoorWijzigen

Set the maximum zoom leven for the 'Open-to-edit' context menu item.

merkbandafstand

Set to x meter for all markings in the stukslijst FttH

mnuOverzichtKastindelingNew

Set to show the frame in the old style or new style.

nMagCocon11Starten

Set to 0 to stop from starting Cocon 11, set to 1 to allow certain users to start Cocon 11, set to 2 to allow all users to start Cocon 11.

pps_available_sales

Set to j to make the termination unit PPS available to sales, set to n to disable.

projecttranslate

Set to translate the projectnumber by string. The string CONTRACTNR is replaced by the given value.

registreerklantbijgebouw

Set to allow registering customer names to a building.

registreerradiosites

Set to allow registering radio data to a building.

sChangeDateWhilCopyFile

Set to copy the accepted documents to a folder name date NOW.

sDefaultDucts

Set to specify which ducts should be default. Both amount of ducts and duct diameter may be entered.

sEmailDomeinnaam

Set to the domain used for sending an email to customers.

sNameForContractor

Specify the name used for a 'contractor'.

sProxyServer_OBS

ProxyServer setting for mail send by Cocon11.

sTabborLabel

Definition for the label of the tabbor table.

sTekeningExtentie

Set the extension of the drawing, used when setting a hyperlink to a drilling. Default value is .dwg

sTypesOfRC

When not set to n, an extra later RC_ACCESS is created. When created in coconwebmaps, it is also loaded into the geography.

sVezelStatusNietToegestaanByLijnbenaming

 

sZetDezeStatusOverGeheleVerbinding

Used to set status of the complete connection. If the status of the fiberusage is within the series, the status of the entire connection is replaced.
Default = 0,1,3,6,7,8

vMapThemes

Set to 0 to use the old layer methode. Set to the currect xml version to activiate the xmlStyling.

 

 


Last edited: 02-10-2017

Afbeeldingen_LogoSpeerIT

Afbeeldingen_CoconLogoWitKlein

© Speer IT B.V. 1999-2018