Report on rack lay- out

<< Click to Display Table of Contents >>

Navigation:  Reports > Termination >

Report on rack lay- out

This function displays a report on the rack layout. The locations of the patch panels and splice shelf units in the rack will be displayed. Also the location of blocked height units.

 

By typing (a part of) the rack name in the search field, the racks that match the search criteria will be presented in 'a tree view'. By clicking on a rack name in the tree view, the content of the rack will be presented in details.

There will be content displayed for each rack separately. Also, there will be a schematic representation to show where each patch- and spliceunit is placed in the rack.

By selecting a patch- or splice unit you can switch between the different patch- and spliceunits by using the corresponding buttons.

 

By using a double click a patch- or spliceunit it's possible to get directly linked to the screen of the selected patch- or spliceunit.The front- and backside are displayed next to each other in this overview.
The unit can be replaced (drag) easily to the front- or backside. By using a right mouse click on a unit it's possible to place the unit back in stock.
The units are in stock when it's not clear in which position the unit must be placed in the rack.

When a unit is placed in the rack it will be displayed in the color of the associated status.

 

warning

When the units are not placed  or cannot placed correctly in the rack check the base tables and fill the empty fields or the incorrect fields.

Before a rack can be used in Cocon, the rack must be added to the base tables in the 'maintain type of frames' screen.

 

The following actions may be taken from this screen:

clip1581

In the yellow search field you can search for the specified object.

clip1582

Search / Filter.

clip0937

Unlock/Lock the rack content.

clip0767

Go to the "Enter/change Patch panel" screen.
You may also reach this screen by double click on the unit.

clip0768

Go to the "Enter/change splice shelf unit" screen.
You may also reach this screen by double click on the unit.

clip0769

Go to the "Fiber usage" screen

clip0770

Create report on patch positions, which do not end on customer location.

clip0771

Change frame information.

clip0772

View a report with all end points for this frame.

clip0773

View a report on usage by customers of all involved cables.

clip0774

Create rack layout (in Excel) for printing.

clip0775

Displays a list of files linked to the this frame.

clip0776

Save the changes.

clip0777

Zoom in on the frame.

clip0778

Zoom out of the frame.

clip0779

Place the frame in the entire screen.

clip0780

Count the frame (hight unit) the other way around.

 

 

 


Last edited: 31-10-2017

Afbeeldingen_LogoSpeerIT

Afbeeldingen_CoconLogoWitKlein

© Speer IT B.V. 1999-2018